- Characteristic and Advantage
- Electrical Characteristics
- Support mainstream ISO15693 protocol tag (TI, PHILIPS, ST, INFINEON, FUJITSU, EM) omni-directional operation;
- Advanced anti-collision algorithm, high identification rate;
- Typical Gate width up to 90cm*;
- 2 line infrared motion sensor with intelligent movement direction determination and personnel counting;
- Low power dissipation design with RF output power over 4Watt;
- Support single gate standalone or multiple gate synchronized work mode;
- Configuration various alarm modes;
- Support EAS/AFI security surveillance;
- Support RS232/RS485 and TCP/IP interface;
- Support plug-in camera, large screen display/ television to realize control and management in a more intuitive way.
*Effective distance depends on protocol, tag and working environment.
APPLICATION INFORMATION
Serial communication setting: 38400bps, E, 8, 1
Serial port IF1 and IF2 DB9 socket definition:
PIN |
SYMBOL |
COMMENT |
1 |
NC |
Reserved |
2 |
TXD |
RS232 data output (RS485 R-) |
3 |
RXD |
RS232 data input (RS485 R+) |
4 |
NC |
Reserved |
5 |
GND |
Ground |
6 |
NC |
Reserved |
7 |
NC |
Reserved |
8 |
NC |
Reserved |
9 |
NC |
Reserved |